CONSTRUCTION PROCESS OF JOIST SLAB and vault    construction process and vault JOIST SLAB   
  
 
     This          system   constructive        has the advantage of building slabs       without       Cimbrian       that to support the arches into the joists       entire surface is covered.       
    The joists are supported       on walls or beams,       bracing       temporarily.       
     The       items      light are the arches       resting on the joists,      lighten the slab  and        serve      formwork to       concrete cast on site.       
    A       mesh layer       electro welded       extends throughout the slab,       on elements light       to serve as reinforcement       against temperature effects       as       compression layer.       
    The       slab is integrated into the structure       the walls and castles       through specific channels (channels enclosure)       that       slip on the walls       the perimeter.       
    On this particular school  whole      to fill the veins       and form a compression layer        on      light elements (with a minimum thickness of three centimeters).   
        SLAB STEPS TO BUILD A ceiling joist and vault:   
     
  
    STEP 1: SHORING   
  
 
    braces are placed and support beams and leveling.       and removed after 7 days of strained layer compression.        poles are placed      4 "x 4"       each 1.50m      and        beams of the same section each 1.60m       to serve as provisional support to the joists.   
  
 
   
 
   
 
   
 
   
  
    STEP 2: PLACEMENT OF JOISTS   
  
 
    Place joists       supported        on      the walls we have defined as       Chargers       our       slab.  joists      manually placed       boots on the walls.      From wall  boot placed the           first joist      .    NOTE: It is recommended that compression strain layer beams with       or        chains      enclosure.   .       The joists should be supported on the walls       or at least elements loaders       inches.       For example       if you have a clear       free three meters       more inches      support        on each wall,       joist       required       must have       3.10m     total length     
  
 
   
 
   
 
   
 
   
  
    STEP 3: ALIGN JOISTS   
  
 
    slabs are placed at the ends       of the beams to obtain the correct separation of       these also facilitate       the       subsequent placement of other slabs in alignment.   
  
 
   
 
   
 
   
  
    STEP 4: PUT  Cove  
   
  
    caring slabs are placed firmly seated and close together.  placement      also done manually.   
  
 
   
 
   
 
   
 
  
 
    STEP 5: ATTACH WIRING   
  
 
     After      the vaults       have been in place,       hoses are placed       for electrical installation. These       put on the walls       and bovedillas.Donde holes of output required for an outbreak that vault is removed, the installation gets to the output of focus, put under an arch and then you reinforce it with small rods or mesh the hole and then just puts his cast   concreto.Asi      also      carried out the hydraulic       and necessary health.   
  
 
   
 
   
  
    STEP 6: PLACE MESH WELDED   
  
 
    short is presented and the required size and tied with wire annealing top rod of the joists and       chains enclosure.     NOTE:   layers       3 to 4 cm wire mesh is recommended     -    welded  66x10x10 and 5 cm layers of welded wire mesh 66x8x8. The welded wire mesh       on the floor is cut to size,      later        climbs the slab under construction       and tied with wire annealed to the upper rod joists and chains enclosure.   
   
 
   
 
   
 
   
 
  
 
    STEP 7: STRAINED LAYER COMPRESSION   
  
 
    holes are plugged at the ends of the slabs and / or those that have been cropped to fit the clear. It       perfectly wet joists and slabs and cast           of 3 to 5 cm of concrete according to the mesh. It       recommended to wet the arches to       get       greater      adhesion        with the compression layer. The      concrete        must       have a minimum strength of         F ° C = 200 kg/cm2. This step of the casting layer     compression layer (concrete) should be performed in a single operation.     
  
 
   
 
   
 
   
 
   
 
  ----------------- -------------------------------------------------- 
  
 
   
 